1PRODUCT CHECKING AND PARTS IDENTIFICATIONUnpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to ensure thatthe product agrees with your order and the inverter is intact.●Capacity plateFR-D740036-ECCapacity plate FR-D740-036-EC XXXxxxInverter type Serial numberSymbolVoltage classDisplays theD740Three-phase 400Vrated currentclass●Rating plateD720SSingle-phase 200VRating plateMITSUBISHIInverter typeFR-D740-036-ECclass.Installation of the inverterEnclosure surface mountingRemove the front cover and wiring cover to fix the inverter to the surface.-FR-D740-012to160,FR-D720S008to042:FR-D720S070and100Front coverWiring coverWiring coverNoteWhen encasing multiple inverters,install them in parallel as acooling measure.When using the inverters at the surrounding air temperature of10cm or more40C or less,the inverters can be installed without any clearancebetween them (0cm clearance).When surrounding airtemperature exceeds 40C,clearances between the invertersshould be 1cm or more(5cm or more for the FR-D740-120 ormore).10cm or moreInstall the inverter vertically.Refer to the dearanceson the left.77PRODUCT CHECKING AND PARTS IDENTIFICATION·General PrecautionThe bus capacitor discharge time is 10 minutes.Before starting wiring or inspection,switch power off,wait for more than 10minutes,and check for residual voltage between terminal and with a meter etc,to avoid a hazard of electrical shock.●EnvironmentBefore installation,check that the environment meets following specifications.-10C to +50C (non-freezing)MeasurementpositionSurrounding Air35cm5cmTemperatureMeasurement5cmAmbient humidity90%RH maximumStorage temperature-20C to +65C (Temperature applicable for a short time,e.g.in transit.)AmbienceIndoors (free from corrosive gas,flammable gas,oil mist,dust and dirt)Maximum 1000m above sea level for standard operation.After that derate by 3%for every extra 500mupto2500m(91%).5.9m/s2 or lessNoteInstall the inverter on a strong surface securely and vertically with bolts.Leave enough clearances and take cooling measures.Avoid places where the inverter is subjected to direct sunlight,high temperature and high humidity.Install the inverter on a non-bustible wall surface.22OUTLINE DIMENSION DRAWINGSW1(Unit:mm).Three-phase 400V classInverter TypeW1H1DFR-D740-012FR-D740-022129.5FR-D740-03610896128118135.5FR-D740-050155.5FR-D740-080165.5FR-D740-120220208150138FR-D740-160155.Single-phase 200V classInverter TypeW1HH1DFR-D720S-00880.5FR-D720S-0146856FR-D720S-025128118142.5FR-D720S-042162.5FR-D720S-07010896155.5FR-D720S-1001401281501381453WIRING3.1Terminal connection diagramSource logicMain circuit terminalWhen ecting a DC reactor,remove theSingle-phase power input6 A brake transistor is not built-in to theMCCBMCSingle-phaseC.L1EarthRAC powerGround)7Install a thermal relay to prevent ansupplyJumperPRtor can not be connectedto the FR-D7205-008 and 014.)MCCBMC.P1MotorThree-phaseR/L1AC powerS/L2IMsupplyT/L3EarthMain circuit(Ground)-Earth(Ground)Control circuitControl input signals (No voltage input allowed)Relay outputForwardSTFTerminal functions varyTerminal functions varywith the input terminalReverseSTRRelay outputrotation startAFault output)P.182)HighRHspeedMulti-speed selectionMiddleRMOpen collector outputspeed2 When using terminals PC.LowRLRUNSD as a 24VDC powerspeedRunningsupply.take care nottoSDselectionPC-SD.SEOpen collector output monContact input monSink/source mon24VDC power supplyContact input mon(Common for extemal power supply transistor)AMO(+)Analog signal outputcan be changed by analog(0 to 10VDC)220 to 5VDC *3(0 to 10VDC)5PU75(Analog mon)connecto(Pr.267).Set theTerminal 4input44 to 20mADC(Currentto select voltage input (04Voltage/current4input switch *4tly.NOTETo prevent a malfunction caused by noise,separate the signal cables more than 10cm from the power cables.After wiring,wire offcuts must not be left in the inverter.Wire offcuts can cause an alarm,failure or malfunction.Always keep the inverter clean.When drilling mounting holesin an enclosure etc.,take care not to allow chips and other foreign matter to enter the inverter.WIRING3.2 Main circuit terminal specifications3.2.1Terminal arrangement of the main circuit terminal,power supply and the motorwiring.Three-phase 400V classFR-D740-012t0080FR-D740-120,160JumperJumperScrew size(M4)Screw size (M4)P1Screw sizeMPower supply4)MotorPower supply MotorNOTEMake sure the power cables are connected to the R/L1,S/L2,T/L3.(Phase need not be matched.)Never connect thepower cable to the U,V,W of the inverter.Doing so will damage the inverter.Connect the motor to U,V,W.Turning on the forward rotation switch (signal)at this time rotates the motorcounterclockwise when viewed from the load shaft.Single-phase 200V classFR-D720S-008to042FR-D720S-070and100JumperScrew size (M3.5)JumperScrew size (M4)의MPower supplyPower supplyMotor5WIRING3.2.2Cables and wiring length(1)Cable sizes etc.,of the main control circuit terminals and earth (ground)terminalsSelect the remended cable size to ensure that a voltage drop will be 2%maxIf the wiring distance is long between the inverter and motor,a main crcuit cable voltage drop will cause the motor torque todecrease especially at the output of a low frequency.The following table indicates a selection example for the wiring length of 20m.Three-phase 400V class (when input power supply is 440V)Cable SizeCrimpingTerminalTighteningTerminalHIV Cables,etc.(mm2).1AWG+2PVC Cables,etc.(mm)Applicable InverterModelScrewTorqueSize+4NmR/L1R/L1EarthR/L1R/L1EarthS/L2U,V.WS/L2U.V,W(ground)S/L2U.V.WS/L2 U.V.W(ground)T/L3T/L3cableT/L3T/L3cableFR-D740-012to080M41.52-422214142.5FR-D740-120M41.55.542-43.523.512144254FR-D740-160M41.55.545.5-43.53.53.5121244Single-phase 200V class (when input power supply is 220V)Cable SizeCrimpingTerminal TighteningTerminalApplicable InverterHIV Cables,etc.(mm2).1AWG+2PVC Cables,etc.(mm)ScrewTorque3ModelSize+4N.mEarthEarthL1,NU,V,W(ground)L1,N U,V,W(ground)cablecableFR-D720S-008to042M3.51.22-3.52-3.52214142.5252.5FR-D720S-070M41.5314142.52.52.5FR-D720S-100M41.55.543.523.5121442.541The cable size is that of the cable (HI cable (600V class 2 vinyH-insulated cable)etc.)with confinuous maximum permissible temperature of 75'C.Assumesthat the surrounding air temperature is 50C or less and the wiring distance is 20m or less.2The remended cable size is that of the cable (THHW cable)with confinuous maximum permissible temperature of 75'C.Assumes that the surrounding(Selection example for use mainly in the United States.)3The remended cable size is that of the cable (THHW cable)with confinuous maximum permissible temperature of 70C.Assumes that the surroundingair temperature is 40'C or less and the wiring distance is 20m or less.(Selection example for use mainly in Europe.)The terminal screw size indicates the terminal size for R/L1,S/2,TAL3,U,V,W,PR,+,-,P1 and a screw for earthing (grounding).(For single-phase power input,the terminal screw size indicates the size of terminal screw for L1,N,U,V,W,and a screw forearthing (grounding).)NOTETighten the terminal screw to the specified torque.A screw that has been tighten too loosely can cause a short circuitor malfunction.A screw that has been tighten too tightly can cause a short circuit or malfunction due to the unitbreakage.Use crimping terminals with insulation s leeve to wire the power supply and motor.The line voltage drop can be calculated by the following formula:line voltage drop [V]=3 x wire resistance[m/m]x wiring distance[m]x current[A]1000Use a larger diameter cable when the wiring distance is long or when it is desired to decrease the voltage drop (torquereduction)in the low speed range.6WIRING(2)Total wiring lengthThe overall wiring length for connection of a single motor or multiple motors should be within the value in the table below.200V class070(carrier frequency)008014025042or More1(1kHz)or less200m200m300m500m500m2to1530m100m200m300m500m(2kHz to 14.5kHz)400V class012022036050080(carrier frequency)or More1(1kHz)or less200m200m300m500m500m2to15(2kHz to 14.5kHz)30m100m200m300m500mTotal wiring length(FR-D720S-070 or more,FR-D740-080 or more)500m or less300m300m300m+300m=600mWhen driving a 400V class motor by the inverter,surge voltages attributable to the wiring constants may occur at themotor terminals.deteriorating the insulation of the motor.Take the following measures(1)or(2)in this case(1)Use a "400V class inverter-driven insulation-enhanced motor"and set frequency in Pr:72 PWM frequency selectionaccording to wiring lengthWiring Length50m to 100mExceeding 100mCarrier frequency14.5kHz or less8kHz or less2kH也or less(2)Connect the surge voltage suppression filter(FR-ASF-H/FR-BMF-H)on the inverter output side.NOTEEspecially for long-distance wiring,the inverter may be affected by a charging current caused by the straycapacitances of the wiring,leading to a malfunction of the overcurrent protective function,fast response current limitfunction,orstall prevention function or a malfunction or fault of the equipment connected on the inverter output sideIf fast-response current limit malfunctions,disable this function.When the stall prevention function misoperates,oprion for details of surge voltage suppression filter(FR-ASF-H/FR-BMF-H).When using the automatic restart after instantaneous power failure function with wiring length exceeding below,Motor capacity0.1K0.2K0.4KWiring length20m50m100m3.3Control circuit specifications(1)Control circuit terminal layoutRemendedcable size:0.3mm2to0.75mm2RLMR四SD PC STF STR(2)Wiring methodUse a bar terminal and a cable with a sheath stripped off for the control circuit wiring.For a single wire,strip off the sheath ofthe cable and apply directly.Insert the bar terminal or the single wire into a socket of the terminal.1)Strip off the sheath about the size below.If the length of the sheath peeled is too long.a short circuit may occur amongneighboring wires.If the length is too short,wires might e off.Cable stripping sizeWire the stripped cable after twisting it to prevent it frombeing loose.In addition,do not solder it.10mm2)Crimp the bar terminal.Insert wires to a bar terminal,and check that the wires e out for about 0 to 0.5 mm from a sleeve.CableCheck the condition of the bar terminal after crimping.Do not use a bar terminal of which the crimping is inappropriate,orthe face is damaged.UnstrandedwiresWires are not insertedDamagedCrumpled tipinto the shellIntroduced products on bar terminals (as of Mar.,2008)Bar Terminal ModelWire Size (mm2)MakerWith Insulation SleeveWithout Insulation Sleeve0.3.0.50.75A0,7510GYA0,75-101Al 1-10RDA1-10Phoenix Contact Co.,Ltd.1.25.1.5A11,5-10BKA1,5-100.75 (for two cables)AI-TWIN 2 X 0,75-10GYBar terminal crimping tool:CRIMPFOX ZA3(Phoenix Contact Co.,Ltd.)WIRING3)Insert the wire into a socket.When using a stranded wire without a bar terminal,push a open/close button all the way down with a flathead screwdriver,and insert the wire.L Open/close buttonFlathead screwdriverNoteWhen using a stranded wire without a bar terminal,twist enough to avoid short circuit with a nearby terminals orwires.Place the flathead screwdriver vertical to the open/close button.In case the blade tip slips,it may cause to damage ofinverter or injury.Wire removalPull the wire with pushing the open/close button all the way down fimmly with a flathead screwdriver.Open/close buttonFlathead screwdriverNoteUse a small flathead screwdriver(Tip thickness:0.4mm/tip width:2.5mm).If a flathead screwdriver with a narrow tip is used,terminal block may be damaged.Place the flathead screwdriver vertical to the open/close button.In case the blade tip slips,it may cause to damage ofinverter or injury.Wiring instructions1)Teminals PC.SE and 5 are mon to the l/O signals.Do not earth (ground)them.2)Use shielded or twisted cables for connection to the control circuit terminals and run them away from the main and powercircuits (including the 200V relay sequence circuit).3)Use two or more parallel micro-signal contacts or twin contacts to preventcontact faults when using contact inputs since the control circuit input signalsare micro-currents.4)Do not apply a voltage to the contact input terminals (e.g.STF)of the controlcircuit.Micro signal contactsTwin contacts5)Always apply a voltage to the fault output terminals (A.B.C)via a relay coil,lamp,etc.6)It is remended to use the cables of 0.3mm-to 0.75mm-gauge for connection to the control circuit terminals.If the cable gauge used is 1.25mm or more,the front cover may be lifted when there are mamy cables running or thecables are run improperly,resulting in a fall off of the operation panel.7)The maximum wiring length should be 30m.
文档评分
    请如实的对该文档进行评分
  • 0
发表评论

"π³ 实操派",培养中高端PLC工程师,PLC培训-Codesys培训

项目实战 手把手教学 微信&电话 15850116008
超2000节系统化课程,汇川优秀自动化讲师亲授!学一门Codesys,玩800家PLC仅剩少量名额
点击免费试听

到实操派,学PLC就是快!

扫码领取工控文库VIP

钻石VIP先到先得

服务电话 & 微信:9:00-22:00

15850116008

苏州实操派科技有限公司

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

Copyright © 苏州实操派科技有限公司 2022 到实操派,学PLC就是快!工业自动化业务培训适用人群:成人 ( 苏ICP备2022021576号-3 )

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

返回顶部