苏州实操派科技有限公司官网-实操派教育科技,汇川技术PLC培训,实操派PLC培训,苏州PLC培训机构

首页国外自动化施耐德变频器ATV61 LonWorks card VW3A3312-EN-v2(1765273)
MENGMINGMIN

文档

1817

关注

0

好评

0
PDF

ATV61 LonWorks card VW3A3312-EN-v2(1765273)

阅读 367 下载 250 大小 920.45K 总页数 54 页 2026-01-09 分享
价格:¥ 1.00
下载文档
/ 54
全屏查看
ATV61 LonWorks card VW3A3312-EN-v2(1765273)
还有 54 页未读 ,您可以 继续阅读 或 下载文档
1、本文档共计 54 页,下载后文档不带水印,支持完整阅读内容或进行编辑。
2、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
4、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。 免责声明: 版权:我们作为资源的整理方,所有资源均来自互联网的优秀作者们,版权归原作者或企业所有。
申明:任何使用本站收集的资源产生的不测后果,本站不对此负任何责任。
1.Important informationNOTICERead these instructions carefully,and look at the equipment to bee familiar with the device before trying to install,operate,or maintain it.The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to callattention to information that clarifies or simplifies a procedure.The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists,which will resultin personnal if the instruction are not followed.This is the safety alert symbol.It is used to alert you to potential personal injury hazards.Obey all safety messages thatfollow this symbol to avoid possible injury or death.A DANGERDANGER indicates an imminently hazardous situation,which,if not avoided,will result in death,serious injury,or equipment damageA WARNINGWarning indicates a potentially hazardous situation,which,if not avoided,can result in death,serious injury,or equipment damage.A CAUTIONCAUTION indicates a potentially hazardous situation,which,if not avoided,can result in injury or equipment damage.PLEASE NOTEElectrical equipment should be serviced only by qualified personnel.No responsibility is assumed by Schneider Electric for any2.Before you beginRead and understand these instructions before performing any procedure with this drive,in order to pletely and correctlyutilize excellent performance of this unit.Besides this user manual,you will find in the chapter"Documentation structure"which manuals we advice you to read to develop softwaremunicating with Altivar 61.If you need support,please contact our sales offices.After reading this instruction manual,please keep it handy for future referenceA DANGERHAZARDOUS VOLTAGERead and understand the Installation Manual before installing or operating the Altivar 61 drive.Installation,adjustment,repair,andmaintenance must be performed by qualified personnel.The user is responsible for pliance with all international and national electrical standards in force concerning protective groundingof all equipment.Many parts of this variable speed drive,indluding the printed circuit cards,operate at the line voltage.DO NOT TOUCH.Use only electrically insulated tools.DO NOT touch unshielded ponents or terminal strip screw connections with voltage present.DO NOT short across terminals PA and PC or across the DC bus capacitors.Install and cose all the covers before applying power or starting and stopping the drive.Before servicing the variable speed driveDisconnect all power.Place a "DO NOT TURN ON"label on the variable speed drive disconnect.Lock the disconnect in the open position.Disconnect all power including external control power that may be present before servicing the drive.WAIT 15 MINUTES to allow theDC bus capacitors to discharge.Then follow the DC bus voltage measurement procedure given in the Installation Manual to verify thatthe DC voltage is less than 45 VDC.The drive LEDs are not accurate indicators of the absence of DC bus voltage.Electric shock will result in death or serious injury.A CAUTIONDAMAGED EQUIPMENTDo not install or operate any drive that appears damaged.Failure to follow this instruction can result in injury or equipment damage.53.IntroductionThank you for purchasing the LonWorks option card (V3A3312)for Altivar 61 drive.By Installing this board into the Altivar 61,data munication can be made with a host puter or other device via LonWorks work.The munication card has an open-style 3-pin connector for connection to the work.It supports free topology at 78 kbit/s.Data exchanges give access to all Altivar 61 functions:Control (start,stop,reset,setpoint),Monitoring(status,current,voltage,thermal state..).Diagnostics (alarms).The graphic display teminal or the integrated display terminal can be used to access numerous functions for munication configurationand diagnostics.The LonWorks resource files (.XIF...)that provide the work configuration tools (LonMaker...)with device information are available on theWeb site www.telemecanique. and on the CDROM delivered with each drive.The plug-in software tool that provides easy access to setting-up,testing and monitoring the ATV61 drive is also available on the Web sitewww.telemecanique. and on the CDROM delivered with each drive.4.Documentation structure■LonWorks manualThe present LonWorks user manual describes:connection to LonWorks,configuration of the munication-specific parameters via the integrated HMI or the graphic HMI,·diagnostics,·works variables.You will also find important information in other Altivar 61 technical documents.They are available on the Web site www.telemecanique.and on the CDROM delivered with each drive.■Installation manualThe installation manual describes:how to assemble the drive (particularly how to mount the LonWorks card),how to connect the drive.■Programming manualThe programming manual describes:the functions and parameters of the drive.how to use the drive HMI (integrated HMI and graphic HMI).Communication parameters manualThe Communication parameters manual describes:the operating modes specific to munication (CiA 402 state chart),the interaction between munication and local control (HMI and terminals).the drive parameters with specific information for use via a munication work (addresses,formats,etc).When using the LonWorks card,some sections of the Communication parameters manual are not relevantprofiles,·DSP402 profile.The description of drive parameters is useful only if you use the parameters access function of the LonWorks card (nviParamCmd.75.NotationRegistered trademarksEchelon,LonWorks,LONMARK,LonTalk,Neuron are the registered trademarks or the trademarks of Echelon Corporation in theUSA and other countries.Drive terminal displaysThe graphic display terminal menus are shown in square bracketsExample:[1.9 COMMUNICATION].The integrated 7-segment display terminal menus are shown in round brackets with a "at the end.Example:(Con-).Parameter names displayed on the graphic display terminal are written in square brackets.Example:[Fallback speed]Parameter codes displayed on the integrated 7-segment display terminal are written in round bracketsExample:(L FF).■FormatsHexadecimal values are written as follows:16#or 0xBinary values are written as follows:2#■AbbreviationsO=OptionalM=Mandatory6.Hardware setup6.1.ReceiptCheck that the card reference printed on the label is the same as that on the delivery note corresponding to the purchase order.Remove the option card from its packaging and check that it has not been damaged in transit.6.2.Check listLonWorks car is shipped together with the following accessories.On opening the packing case,check if it contains:the mounting instruction sheet.·the led label,.·the Neuron ID label.Note:no paper user manual is delivered with the card.The user manuals are delivered on the CD Rom shipped with each Altivar drive.6.3.Hardware descriptionLEDsService pin push-buttonOpen style 3-pinconnector6.4.Installing the card in the driveRefer to the installation manual.7.Connecting to the bus7.1.TopologyThe LonWorks munication card supports free topology wiring and operates as well with bus,loop or star topologies:Free topology systemFree topology has many advantages:1 The installer is free to select the method of wiring that best suits the installation,reducing the need for advanced planning and allowinglast minute changes at the installation site.2 If installers have been trained to use one style of wiring for all installations,free topology technology can be introduced without requiringretraining.3 Retrofit installations with existing wiring plants can be acmodated with minimal,if any rewiring.Typical wiring topologiesTerminationSingly terminated bus topologyTerminationTerminationTeminationDoubly terminated bus topologyStar topologyTerminationTerminationMixed topologyLoop topology107.Connecting to the bus7.2.Cable routing practicesWhen wiring Altivar 61 drives to a LonWorks work,follow all wiring practices required by national and local electrical codes.Also observethe following guidelines:Avoid areas of high temperature,moisture,vibration,or other mechanical stress.Secure the cable where necessary to prevent its weight and the weight of other cables from pulling or twisting the cable.Use cable ducts,raceways,or other structures to protect the cable.Use these structures for signal wiring paths.They must not containpower wiring.Avoid sources of electrical interference that can induce noise into the cable.Use the maximum practicable separation from such sourcesWhen planning cable routing within a building,follow these guidelinesMaintain a minimum separation of 1 m from the following equipment:air conditioners and large blowers,elevators and escalators,radios and televisions,inter and security systems,fluorescent,incandescent,and neon lighting fixtures.Maintain a minimum separation of 3 m from the following equipment:line and motor power wiring.transfomers,·generators,alternators.When wiring in electrical equipment rooms or large electrical equipment line-ups,observe the following guidelines for cable segregationand separation of circuits:Use metallic conduit for drive wiring.Do not run control work and power wiring in the same conduit.Separate non-metallic conduits or cable trays used to camy power wiring from metallic conduit camrying low-level control work wiringby at least 300 mm.Separate metallic conduits camying power wiring or low-level control work wiring by at least 80 mm.Cross the metallic conduits and non-metallic conduits at right angles whenever power and control work wiring crossAttenuate conducted emissions from the drive to the line in some installations to prevent interference with telemunication,radio,andsensitive electronic equipment.Such instances may require attenuating filters.Consult the Altivar catalog for selection and application ofthese filters.7.3.Wiring the LonWorks connectorThe figures and the table below show the pin-outs of the card connectors.The removable LonWorks female connector attaches to thework cable.2LonWorks card male connectorRemovable LonWorks female connectorPinName1Net A(A)2Shield (S)3Net B(B)Cable sheath should be peeled off by about 10 mm.For wiring work,use a fat blade screwdriver with a 0.6 mm thick and 3.5 mm width bladeTightening torque for the teminal block is 0.5 to 0.6 Nm.7.Connecting to the bus7.4.Line TerminationThe termination is built from the following ponents,where a total termination impedance of approximately 532 is required.C1C1,C2:100F,>50VDoubly terminated bus topology:two terminations,one on each end of the segment,each with R=105
文档评分
    请如实的对该文档进行评分
  • 0
发表评论

"π³ 实操派",培养中高端PLC工程师,PLC培训-Codesys培训

项目实战 手把手教学 微信&电话 15850116008
超2000节系统化课程,汇川优秀自动化讲师亲授!学一门Codesys,玩800家PLC仅剩少量名额
点击免费试听

到实操派,学PLC就是快!

扫码领取工控文库VIP

钻石VIP先到先得

服务电话 & 微信:9:00-22:00

15850116008

苏州实操派科技有限公司

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

Copyright © 苏州实操派科技有限公司 2022 到实操派,学PLC就是快!工业自动化业务培训适用人群:成人 ( 苏ICP备2022021576号-3 )

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

返回顶部