苏州实操派科技有限公司官网-实操派教育科技,汇川技术PLC培训,实操派PLC培训,苏州PLC培训机构

王远诚

文档

769

关注

0

好评

0
PDF

MS系列

阅读 167 下载 233 大小 662.09K 总页数 73 页 2025-03-26 分享
价格: 1 π币
还有 73 页未读 ,您可以 继续阅读 或 下载文档
1、本文档共计 73 页,下载后文档不带水印,支持完整阅读内容或进行编辑。
2、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
4、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。 免责声明: 版权:我们作为资源的整理方,所有资源均来自互联网的优秀作者们,版权归原作者或企业所有。
申明:任何使用本站收集的资源产生的不测后果,本站不对此负任何责任。
CAUTIONVerify that the driver rated voltage coincides with the AC powersupply voltage.Failure to observe this caution can result in personal injury or a fire.Do not perform a withstand voltage test of the driver.It may cause semi-conductor elements to be damaged.To connect a braking resistor,follow in APPENDIX A.Improper connection may cause the unit damaged or a fire.Tighten terminal screws.Failure to observe this caution can result a fire.Never connect the AC main circuit power supply to output terminalsU,V and W.The inverter will be damaged and invalidate the guarantee.OPERATION公WARNINGOnly tum ON the input power supply after replacing the front cover.Do not remove the cover while current is flowing.Failure to observe this warning can result in an electrical shock.CAUTIONSince it is easy to change.Operation speed from low to high speed,verify the safe working range of the motor and machine before op-eration.Failure to observe this caution can resuit in personal injury andmachine damage.Do not change signals during operation.The machine or the inverter may be damagedAll the constants of the inverter have been preset at the factory.Do not change the settings unnecessary.MAINTENANCE AND INSPECTIONWARNINGNever touch high-voltage terminals in the driver.Failure to observe this warning can result in an electrical shockReplace all protective covers before powering up the inverter.To remove the cover,make sure to shut OFF the molded-case circuitbreaker.Failure to observe this warning can result in an electrical shockPerform maintenance or inspection only after verifying that theCHARGE LED goes OFF,after the main circuit power supply isturnned OFFThe capacitors are still charged and can be dangerous.Only authorized personnel should be permitted to perform mainte-nance,inspections or parts replacement.Failure to observe this waming can result in an electrical shock.-V-CAUTIONThe control PC board employs CMOS ICs.Do not touch the CMOSelements by hand.They are easily damaged by static electricity.Do not connect or disconnect wires or connectors while power isapplied to the circuit.Failure to observe this caution can result in personal injury.OTHERSWARNINGNever modify the product.Failure to observe this warning can result in an electrical shock orpersonal injury and will invalidate the guarantee.-V-CONTENTS1.RECEIVING12.SPECIFICATIONS…3.DIMENSION DRAWINGS34.INSTALLATION..............55.DESCRIPTION OF TERMINALS1137.FUNCTIONS DESCRIPTION………148.DISPLAY ERROR CODES.............459.HARDWARE PROTECTIVE FUNCTIONS...................4810.PRECAUTIONS…4911.TROUBLESHOOTING5012.APPLICATION……5113.INVERTER SELECTION5514.APPENDIX .........57A.Optional braking resistor57B.Terminal wiring diagram....58591.RECEIVINGThis MS series AC drive has gone through rigorous quality control testsat the factory before shipment.After receiving the AC drive,please checkfor the following(1)No damage is found on each product after shipping.(2)The product is as ordered (check the nameplate,voltage and fre-quency).(3)A set of inverter unit and instruction manual is contained in thepackageFor any irregularity,contact the sales shop where you purchasedimmediately.(4)Description of name plateADLEEPOWER⑧IPM INVERTERVER D 04MODEL MS2-115 VER D04SOFTWARECAPACITY 3.1KVA (1.5KW/2HP)OUTPUT CURRENT8]AHARDWAREADLEE POWERTRONIC CO.,LTD.VERSIONMODEL:MS 2-115MS seriesMax Applicable motor(4 pole)Single PhaseVoltage class102:0.2KW104:0.4KW107:0.75KW2:220V115:1.5KW122:2.2KW12.SPECIFICATIONSModelMS2Voltage1ψ220VAC±10%Model NoMS2-102MS2-104MS2-107MS2-115MS2-122Input Frequency50HZ~60HZ±10%Output VoltageOutput Frequency0.5~800HZOutput1.6A3A5A8A11ARated current(A)Capacity (KVA)0.6 KVA1.9 KVA3.1 KVA4.2 KVALargest motor0.2KW0.4W0.75KW2.2KWKW(4 polesControlSine wave pulse width modulationBrakingRegenerative discharge brakingOver currentCapacity150%of rated current 1 minute)Acceleration time0.1~6000SECDeceleration time0.16000SECFrequencyDigitalUse keyboardfor setting and confirm bysettingAnalogBy frequency knobDisplay typeLED DigitsCooling MethodSelf-cooledSelf-cooledSelf-cooledAir-cooledAir-cooledDimension drawingFiglFig 1Fig 1Weight (NW.KG)1.2KG1.2KG1.3KG1.3KG1.4KG23.DIMENSION DRAWINGSUnit:mm101113Fig 13Unit mm104104115.5Fig 244.INSTALLATIONInadequate environment around installation site and installationsurface can result in damage to the inverter.Before operating the MS series inverter,please check the followingpoints(1)Avoid high temperature,high humidity,easy-to-dew ambient envi-ronment.Don't expose to dust or dirt,corrosive gas,and coolantmist,and direct sunlight.Place the unit in a well-ventilated room.(2)Avoid a place subjected to substantial vibration.(3)When installing the unit within the cabi.Please pay attention toventilation and limit the ambient temperature in between-10C~45℃.(14℉113℉).(4)Use a nonflammable material,such a steel sheet on the wall forinstallation.(The rear side will generate heat)(5)Install the unit always vertically with a marginal spacing around.5 cm4 cm5
文档评分
    请如实的对该文档进行评分
  • 0
发表评论

"π³ 实操派",培养中高端PLC工程师,PLC培训-Codesys培训

项目实战 手把手教学 微信&电话 15850116008
超2000节系统化课程,汇川优秀自动化讲师亲授!学一门Codesys,玩800家PLC仅剩少量名额
点击免费试听

到实操派,学PLC就是快!

扫码领取工控文库VIP

钻石VIP先到先得

服务电话 & 微信:9:00-22:00

15850116008

苏州实操派科技有限公司

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

Copyright © 苏州实操派科技有限公司 2022 到实操派,学PLC就是快!工业自动化业务培训适用人群:成人 ( 苏ICP备2022021576号-3 )

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

返回顶部