苏州实操派科技有限公司官网-实操派教育科技,汇川技术PLC培训,实操派PLC培训,苏州PLC培训机构

首页国外自动化三菱PLC三菱自动化全系列手册样本 (324)
王远诚

文档

769

关注

0

好评

0
PDF

三菱自动化全系列手册样本 (324)

阅读 504 下载 147 大小 88.57K 总页数 2 页 2025-03-10 分享
价格: 1 π币
下载文档
/ 2
全屏查看
三菱自动化全系列手册样本 (324)
还有 2 页未读 ,您可以 继续阅读 或 下载文档
1、本文档共计 2 页,下载后文档不带水印,支持完整阅读内容或进行编辑。
2、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
4、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。 免责声明: 版权:我们作为资源的整理方,所有资源均来自互联网的优秀作者们,版权归原作者或企业所有。
申明:任何使用本站收集的资源产生的不测后果,本站不对此负任何责任。
MITSUBISHIJY992D66101ADATE:JUNE 1997PROGRAMMABLE CONTROLLERSPAGE:2 OF 2FX2N-422-BD COMMUNICATION BOARDUSER'S GUIDE4.Mounting procedureTurn off the power of the programmable controller,and mount the 422BDusing the following procedure.Remove the panel cover from the top face of the base unit.2 Connect the connector provided on the 422BD to the board mounting connectorprovided on the base unit.Fix the 422BD to the base unit using the M3 self-tapping screws supplied.Tightening torque:0.3 to 0.6 Nem (3 to 6 kgf.cm)Remove the cut out on the left of the panel cover using a tool such as nippers orcutters so that the terminal block can pass through.5.Specification422BD5.1 General specificationGeneral specifications are the same as those for the FXaN series programmable controller.5.2 Power supply specification5.3 Performance specificationThe 422BD requires 60mA 5V DC supplied from theConforming to RS422programmable controller.The 5V DC power capacity of the programmable controllerMaximum transferTotal extension withinis 290 mA maximum.This is used by peripheral units anddistance50m.special function blocks as well as the 422BD.Make sureConnectorMINI DIN 8 pinthat the power capacity does not exceed this value.For thedetails,refer to the hardware manual.CommunicationHalf-duplexmethodmunication systemFor additional current consumption increases,refer tosection 3.ProtocolProgramming protocolNo isolation6.Cautions for use1)When using any 422BD,do not use any other munication format or parameters.If the municationformat or parameters is set,programming is not possible.2)Only one programming tool (such as FX-10P,FX-20P,etc.)should be connected to either the programmingport or the port provided on the 422BD.If a programming tool is connected to both connectors,thefollowing may occur.a)The program inside the programmable controller may not be consistent with the program inside theprogramming tool.If the program is modified or the set value for timers or counters is modified,a partof the program may be damaged and the programmable controller may malfunction.b)When the sampling trace function of the programmable controller is used from both ports,the correctsampling trace result cannot be obtained.7.Diagnostics1)Make sure that the cable connected is correct.2)Make sure that the programmable controller is connected,and that the POWER LED is on.3)Make sure that the munication format is in the initial state(D8120=KO).Check using a peripheral unithow the munication parameters are set.If the no protocol (RS instruction)or the dedicated protocol isselected,set the parameters correctly using the peripheral unit.4)Make sure that the RS,VRRD or VRSC instruction or N:N work setting program is not used in theprogram.If such an instruction is used in the program,delete it,tumn off the power of the programmablecontroller,then turn it on again.5)If the special auxiliary relay M8070 or M8071 is turned on,tum off the relay using the peripheral unit,tumoff the power of the programmable controller,then turn on the power again.
文档评分
    请如实的对该文档进行评分
  • 0
发表评论

"π³ 实操派",培养中高端PLC工程师,PLC培训-Codesys培训

项目实战 手把手教学 微信&电话 15850116008
超2000节系统化课程,汇川优秀自动化讲师亲授!学一门Codesys,玩800家PLC仅剩少量名额
点击免费试听

到实操派,学PLC就是快!

扫码领取工控文库VIP

钻石VIP先到先得

服务电话 & 微信:9:00-22:00

15850116008

苏州实操派科技有限公司

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

Copyright © 苏州实操派科技有限公司 2022 到实操派,学PLC就是快!工业自动化业务培训适用人群:成人 ( 苏ICP备2022021576号-3 )

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

返回顶部