苏州实操派科技有限公司官网-实操派教育科技,汇川技术PLC培训,实操派PLC培训,苏州PLC培训机构

Jason

文档

112

关注

0

好评

0
PDF

P+F屏说明书

阅读 330 下载 249 大小 1.52M 总页数 92 页 2025-03-10 分享
价格:免费文档
下载文档
/ 92
全屏查看
P+F屏说明书
还有 92 页未读 ,您可以 继续阅读 或 下载文档
1、本文档共计 92 页,下载后文档不带水印,支持完整阅读内容或进行编辑。
2、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
4、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。 免责声明: 版权:我们作为资源的整理方,所有资源均来自互联网的优秀作者们,版权归原作者或企业所有。
申明:任何使用本站收集的资源产生的不测后果,本站不对此负任何责任。
1 Important information1.1General informationCopyright 2007 by Pepperl+Fuchs GmbHAll rights reservedThe publisher reserves the right to alter the information and data contained in this manual without priornotice.Unless otherwise indicated,the pany names as well as other names and data used in theexamples are purely fictitious.The publisher may have registered patents or pending patent applications for subject matter coveredin the manual.This manual does not give you license to these patents.Limited warranty:No warranty is provided for the accuracy of the information contained in this manual.As mistakescannot be entirely avoided despite taking the greatest of care,we would be grateful to receiveinformation about any errors you may discover.The publisher disclaims all legal responsibility orliability for errors as well as for subsequent damages and claims.Microsoft,MS,MS-DOS,Windows 2000,Windows XP Professional and Windows XP embedded areregistered trademarks of the Microsoft Corporation.Manufacturer:Pepperl-Fuchs GmbHLilienthalstr.20068307 MannheimGermanywww.pepperl-fuchs.Tel.0621-776-0Fax0621-776-1000E-Mail:info@de.pepperl-fuchs.Pepperl+Fuchs GmbHPEPPERL+FUCHS1.2Symbols used in this manualWarning:The indicated specifications may not be modified.Non-pliance may result in dangerous situationsand damages.Caution:Careful installation:do not replace electrical fuseswith fuses from different manufacturers.Non-Care -Attentionpliance may result in dangerous situations anddamages.Danger:The product may possibly be negatively impacted ordamaged by foreign influences.Non-hazardousAssembly and installation only in non-hazardousarea:areas.Danger:All safety regulations as well as plianceHazardous areacertificates for hazardous areas must be observedZone 1+2In addition,all regulations (VDE)published by therespective authorities for the application of thehazardous Areadevices in hazardous areas(zone 1 and 2)must beplied with at all times.Additional Info:Information and notices that must be observedadditionally.Pressure load:Significant mechanical pressure or impact loadsmay result in damages.no mechanical Forcetermex:32x_V116_TH_E.D0C/20.10.114/91PEPPERL+FUCHS1.3Safety instructionsThese devices are only allowed to be installed and operated by trained and qualified personnelwho have received suitable instruction in their use.These devices represent state-of-art technology.They are only allowed to be connected tosystems that have been approved by Pepperl+Fuchs GmbH.Never open the devices yourself.They are only allowed to be opened by authorizedPepperl+Fuchs GmbH personnel.Pepperl+Fuchs GmbH is not liable for any resulting damages.The devices are not allowed to be modified or otherwise altered in any way.Pepperl+Fuchs GmbH is not liable for any resulting damages.Please study the "Technical Manual"carefully prior to starting up the devices.The most recent version of the "Technical Manual"is always valid.It is available for downloadingon our web site:://www.pepperl-fuchs.The operating voltage of the devices must not exceed the limits indicated in the technical datasection of the "Technical Manual".In the event of failure to ply,Pepperl+Fuchs GmbH is not liable for any resultingdamages.The user guideline RL 1999/92 EG,the specifications EN 60079-14 and the accident preventionregulations (UW)must be observed.The technical data specified for the hazardous area corresponds to the certified values for theEuropean Ex approval.The user is responsible for ensuring that the devices are suitable for theirintended application and for the prevailing ambient conditions.No warranty can be given by Pepperl+Fuchs GmbH in this connection.Data subject to change without noticetermex32x_V116_TH_E.DOC/20.10.115/91PEPPERL+FUCHS2 StartupThis description of the startup procedure only contains information that is relevant to the TERMEXterminals.Please refer to the respective manuals for details of how to start up the peripheral devices.the ENT-DC power supply unit and the host puter.Proceed as follows to start up the equipment:Switch off the system or machine.Make sure that that the installation area is non-hazardous for the duration of the startup procedureif any non-intrinsically safe voltages need to be wired and/or non-intrinsically safe devices opened.This device is designed for use in the hazardous area(Zones 1 and 2)..The requirements of the applicable explosion protection codes(EN 50014 and following)and theinstallation requirements specified in EN 50039 must be observed when these devices areinstalled.In addition,the technical and electrical data stated in the certificate of conformity for thisdevice must be plied with.This device is only allowed to be started up by trained personnel.The applicable explosionprotection codes must be observed.Please study the current versions of the "TERMEX 22X/32XTechnical Manual"and the "TERMEX 2xx/3xx Firmware Manual"carefully prior to starting up thedevice (you can download the latest versions from www.pepperl-fuchs.).The maximum cable length between the intrinsically safe terminal and the ENT-DC mains bufferstage is 230 m.If peripherals are connected to the terminal,this length is reduced by the length ofthe cable between the terminal and the peripheral.Other lengths are subject to special approval byPepperl+Fuchs.ImportantThe maximum cable length between the intrinsicallysafe terminal and the ENT-...may not exceed definedlength.(see Technical manual ENT-DC-30.technical dataX3 Exi interfaces)The device must be connected to the equipotential bonding conductor(wire cross-section 24 mm2,PA connection on the TERMEX terminal).WarningThe case must be earthed.The earth wire must have across-section of at least 4 mm2 and be as short aspossible./hazardous AreaThe device is not allowed to be modified or otherwise altered in any way.In particular,solderingoperations or repairs are not permissible.Such work may only be carried out by the manufactureror by other authorized persons.If this waming is ignored,the approval for the hazardous area is nolonger valid.Since these devices are intrinsically safe,the connecting leads may also be connected ordisconnected when the unit is live.This is not remended for the following reasons,however:Order when connecting:Connect the GND cables first,then the munication cables and finally the supplyvoltage.Order when disconnecting:Disconnect the supply voltages and the munication cables first,then disconnect theGND cables.termex32x_V116_TH_E.DOC/20.10.116/91PEPPERL+FUCHSConnect the terminal and the power supply unit.Please refer to the section entitled "Terminalassignment"for the wiring diagram.WarningOnly ENT-DC power supply units are allowed to beused.Only the ponents listed in section 4 are allowed tobe used as peripherals,and only in the specifiedhazardous Areaconfigurations.All other ponents require the writtenapproval of Pepperl+Fuchs.All wiring must conform to the latest state of the art aswell as to the wiring diagrams approved byIf the terminal is installed in a front panel,make sure that the mounting depth is sufficient toguarantee the minimum cable radius (please also refer to the dimension drawings and technicaldocumentation provided by the cable manufacturer).Please also make sure that the front panel is not warped,as otherwise proper sealing cannot beguaranteed (IP protection).The 4 or 6 clips for fastening onto the front panel should only betightened gently to achieve an optimum sealing contact.Check that all connectors are correctly assigned prior to starting up the device.An assignment planshowing all the terminal signals together with the wire or connection numbers can be found on therear of the terminal.Only now should you switch on the system or machineThe terminal runs an internal self-test when the auxiliary voltage is activated on the mains bufferstage(e.g.ENT-DC).The display goes dark for approximately 1 second(all pixels are energized)and the intemal hardware is tested.The startup message,the firmware version number and theEXTEC logo are displayed for this time(approximately 4 seconds).The terminal then switches tothe normal operating mode.If the project design data is already loaded,'screen 1'is automaticallydisplayed in ASCll modeIf you are using the device for the first time,you should branch to the intemal setup menu with theshortcut +during the self-test phase in order to check that the values of all themost important parameters are correct("TERMEX 2xx/3xx Firmware Manual").To load the project design data,the terminal must be connected to a PC via the mains buffer stage(e.g.ENT-DC).The mains buffer stage and the PC must be connected to the power supply andswitched on.You must select'Protocols:EXTEC'in the terminal setup menu in order to load theproject design software,because you are now using a standard ASCll protocol.After the data hasbeen loaded successfully,the terminal performs a reset,displays the startup message and runs aself-test.If you want to use a protocol other than the standard ASCll protocol,select the requiredprotocol under 'Protocols...'in the setup menu.The terminal is now ready to use and can be controlled from the connected control puter.Check the functions on the control panelCheck the interaction of the functions with the plete system or machine step by step.termex32x V116 TH E.DOC/20.10.117/91PEPPERL+FUCHSWarningThe system or machine may malfunction if theTERMEX terminal is not correctly connected andconfigured.Care-AttentionWarningThe TERMEX terminal is intended solely for installationin another machine.It is not allowed to be started upuntil the conformity of the final product with the 94/9/ECWamingand 99/92/EC Directives has been established and thisCare-Attentionproduct inspected by an authorized expert inaccordance with EN 60079 and EN 50014 ff.Warning Zone 22After installation cable glands have to be savedwith a suitable adhesive (e.g.Screw stop varnish orLoctite metal adhesive)./hazardous AreaSo the unintentional opening and occurance of dust isprevented.termex:32x_V116_TH_E.D0C/20.10.118/91PEPPERL+FUCHS2.1 Shielding of data cables2.1.1 Shielding conceptThe purpose of cable shielding is usually to improve the signal quality and reduce interference as wellas radiation from electromagic fields.The data cables (RS485,TTY,intrinsically safe circuits,digital inputs/outputs,Ether)must beshielded.The shields must be continuously connected and grounded in order to guarantee thenecessary interference suppression.One of the following three techniques should be used:1.Connect and hard ground both ends of the shield.This method achieves the greatest reduction inelectromagic interference.There is,however,a risk of current loops with high pensatingcurrents.These currents can lead to safety problems if their values are excessive.2.Connect and hard ground one end of the shield.This method achieves a reduction inelectromagic interference while simultaneously preventing the above-mentioned current loops.3.Provide a hard connection at one end of the shield (TERMEX)and capacitive grounding at the otherend in the safe area.This method achieves a relatively large reduction in electromagic interferencewhile simultaneously preventing current loops with high pensating currents.A capacitor (approx.10 nF)with a fixed dielectric(ceramic)and a test voltage 1500 V can beinstalled in the safe area for this purpose.The final decision regarding the most suitable shielding concept must be based on a detailedobservation of the equipotential bonding system.Furthermore always observe the clauses 12.2.2.3 and 12.2.2.4 of EN 60079-14.Example 1:If a low-impedance equipotential bonding system (building grounding system)is effective under alloperating conditions,both ends of the shield must be connected and grounded.Caution is necessary,however,if transients that cannot be statically measured are produced when machines are switched.Example 2:If there is no equipotential bonding system or only a poor system,or if the equipotential bondingsystem does not have a very low impedance or has a high noise voltage,variant 2 or 3 should bepreferred.Which of these three concepts is used must be determined by the user on a case-to-case basis (bestinterference suppression and safety).No liability can be accepted by the manufacturer for this decision.A non-connected shield at the VisuNet RM/PC end must always be properly insulated in order toprevent sparking!The Box-10-A(Ethemet patch panel)allows the shield to be optionally connected or not connected toground.It is connected by means of a small contact spring on the DIN rail.Each user must ascertain which form of EMC protection is necessary,and offers sufficient reliabilityfor their particular installation.In systems that are relatively insusceptible to electromagicinterference,it may be adequate to connect and ground only one end of the shield.9/91PEPPERL+FUCHS3 TERMEX Exi terminalTERMEX 220 Text terminalTERMEX 320 Text terminal with large keyboardTERMEX 230 Graphics terminalTERMEX 330 Graphics terminal with large keyboard3.1 Important characteristicsIntrinsically safe control panel for Zones 1 and 2 (EEx ib IIC T4)Classification according to ATEX 95 RL94/9/EG:x Il 2G EEx ib IIC T4bined with mounting case ABG-1 or ABG-3 for Zone 22Classification for Zone 22 Il 3 D X T 134C IP65(Declaration of Conformity)Simple to connect directly to many PLC and puter systemsTypical applications:In processes in the chemical,pharmaceutical and petrochemical industries,in industrial plant engineering,in weighing systems and in metering and filling stationsIndustry-standard design,suitable for:Graphics based control and display functions(TERMEX 220/320:text only)Simple visualization tasksOutput of fault messagesInput of set valuesDisplay of actual valuesCollection of plant data.also with barcode readersGravimetric filling and metering applicationsEasy-to-read LC display 148 x 74 mm,optional with backlightTERMEX 230 /330:text and graphics can be bined as desiredTERMEX 220/320:4 x 20 characters,character height 12 mm,plus softkey bar(5 mm)4 standard fonts,additional fonts can be loaded (TERMEX 230/330 only)Background bitmaps can be loaded (TERMEX 230 /330 only)Graphic elements:pixel,line,block,border,window (TERMEX 230/330 only)Automatic bar graph display (TERMEX 230 /330 only)High EMI resistanceNon-volatile storage of project displays (TERMEX 220/320:text,TERMEX 230/330:text andgraphics)PC based project design of pictures and texts with TERMEXpro for WindowsProject data can also be loaded when the control panel is installedDegree of protection:IP 65 (front)Several versions for panel and surface mountingAdditional binary inputs (NAMUR)and outputs (isolated)as well as serial ports for the hazardousarea available as options-All system parameters verified and selected by means of integrated setup and remote setup on thePCOnly one cable used to connect data and power for all device versionsNoteAll terminals are referred to below in this manual simplyas'TERMEX'unless the differences between theindividual models are significant.termex32x_V116_TH_E.DOC/20.10.1110/91PEPPERL+FUCHS3.2 Overview of modelsAdditional Ex devices can be connected to the TERMEX terminals via serial ports.These ports can beprovided on the terminal as options.ImportantThe ports must be designed to withstand the powerrequirement of the connected devices.A maximum of 3supply circuits can be used with the TERMEX terminal.Care-AttentionConnections:Marking For interfaceDeviceManufacturerPossible ENT-DC voltagesDDigital I/OBarcode readerPSCAN-DP+F7.0 V/8.0 V (7.0 V for EXDS-40)PSCAN-MWMxWMaGD130xTBRICK.k-cellMettler Toledo7.0V18.0V18.5VWMbGD13xTBRICK,k-cellMettler Toledo7.0V18.0V18.5VWMcID5sxMettler Toledo7.0V/8.0V/8.5VWMdD5/083Mettler Toledo7.0V18.0y18.5VWMePM,SM,AMMettler Toledo7.0V18.0Y18.5VID5Mettler ToledoWMhEXDK-LWLPuma /ST3xxMettler Toledo7.0V18.0V18.5VWMi20 mA ppPuma /ST3xxMettler Toledo7.0V/8.0V/8.5VWMiTERMEX aaID5sxWMLPSUxTBRICK ExMettler Toledo7.0V18.0V18,5VWMmPoint Ex8.5 V.240mA ENT-DC-30Exi port version 7WMnPSU non exID-7sxMettler Toledo7.0V18.0V18.5VWMoPSU non exViper ExMettler Toledo7.0V/8.0V18.5VWAEXAWUX-5DMS scale8.5VWEMVS-1.1DMS scale8.0V18.5VWSarxWSaraF-/L-/QS-/X149-/Sartorius7.0V18.0V18.5V11200S scalesWSarb20 mA pp(ENT-Sartorius7.0V/8.0V18.5VDC)Wsard*Ex-PW-SAR-10FC-/IS scalesSartorius7.0V18.0Y18.5VInterface nolonger available!WBaBizerba7.0V18.0V18.5VWBbBizerba7.0V18.0V/8.5VZTExpansionTERMEX K36/7.0V18.0Y18.5VkeyboardKL36Default values are underlinedonly as spare equipment availabletermex32x_V116_TH_E.DOC/20.10.1111/91
文档评分
    请如实的对该文档进行评分
  • 0
发表评论

"π³ 实操派",培养中高端PLC工程师,PLC培训-Codesys培训

项目实战 手把手教学 微信&电话 15850116008
超2000节系统化课程,汇川优秀自动化讲师亲授!学一门Codesys,玩800家PLC仅剩少量名额
点击免费试听

到实操派,学PLC就是快!

扫码领取工控文库VIP

钻石VIP先到先得

服务电话 & 微信:9:00-22:00

15850116008

苏州实操派科技有限公司

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

Copyright © 苏州实操派科技有限公司 2022 到实操派,学PLC就是快!工业自动化业务培训适用人群:成人 ( 苏ICP备2022021576号-3 )

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

返回顶部