苏州实操派科技有限公司官网-实操派教育科技,汇川技术PLC培训,实操派PLC培训,苏州PLC培训机构

耿伟

文档

23

关注

0

好评

1
PDF

功能6:多用户

阅读 435 下载 197 大小 1.94M 总页数 35 页 2025-02-25 分享
价格:免费文档
下载文档
/ 35
全屏查看
功能6:多用户
还有 35 页未读 ,您可以 继续阅读 或 下载文档
1、本文档共计 35 页,下载后文档不带水印,支持完整阅读内容或进行编辑。
2、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
4、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。 免责声明: 版权:我们作为资源的整理方,所有资源均来自互联网的优秀作者们,版权归原作者或企业所有。
申明:任何使用本站收集的资源产生的不测后果,本站不对此负任何责任。
1 Introduction1IntroductionWith multiuser engineering in the TIA Portal you can work with several users jointlyand at the same time on a project.With the parallel editing of different objectswithin a multiuser project,you can considerably shorten the configuration times.1.1OverviewIn TIA Portal as of V14 several server constellations for the functionality ofmultiuser engineering are available to you.This user example describes theparallel editing of projects with a "Temporary Multiuser Server"where the serverfunctionality is realized on one workstation.On the workstation with the multiuserserver,the multiuser server projects are also saved.In order to work with several editors within the framework of multiuser engineeringat the same time,an individual local session has to be created for each editor.Therespective editor can insert their changes in the local session and then check-inand publish these changes in the multiuser server project.After the check-in,thechanges from the local session are again available to all editors in the serverproject.The following figure shows the "Temporary Multiuser Server"server constellation.Figure 1-1:"Temporary Multiuser Server"server constellationServerprojekteLokale SessioLokale Session Lokale SessionThis application example describes the following aspects:Configuring and managing multiuser serverCreating and managing multiuser server projectsCreating and managing local sessionMarking and checking-in objects in the local sessionUpdating local sessionExporting local session as single-user projectEditing objects in the server project viewMultiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/201841 IntroductionNoteOther server constellations can be found in the TIA Portal V15 Online help or thesystem manual "SIMATIC STEP 7 Basic/Professional V15 and SIMATIC WinCCV15:s://support.industry.siemens./cs/ww/en/view/1097552021.2Components usedThis application example was created with the following hardware and softwareponents:Table 1-1:Hardware and software ponentsComponentNumbeArticle numberNoterSIMATIC Field PG M53Alternatively,a differentputer with TIA PortalV15 can also be used.STEP 7 Professional V1536ES7822-1.05-.WinCC Advanced V1536AV210.-5-0TIA Portal Multiuser36ES7823-1A.0.-YEngineering V15Switch11 gigabit workThis application example consists of the following ponents:Table 1-2:ComponentsComponentFile nameNoteDocumentation109740141_MultiUser_Engineering_DOC_v13_en.pdfMultiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/201852 Engineering2Engineering2.1Hardware configurationThe figure below shows the hardware configuration of the application:Theworkstations in this application example are connected in an office work via aswitch.Figure 2-1:Hardware configurationServerMultiuser serverMultiuser projectTIA Portal V15Local sessionTIA Portal V15TIA Portal V15Local sessionLocal sessionClient 1Client 2NoteWhen installing TIA Portal products on the different clients,make sure the samesoftware products of the TIA Portals with identical versions are installed on allthe engineering systems used.NoteTo be able to work with multiuser engineering,a work has to be already setup whilst bearing in mind Windows settings,IP addresses,firewalls etc.The work can also be located within a Windows domainMultiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/20182 Engineering2.2Configuration2.2.1Creating user accounts for clients on the multiuser server PGFor the office work described in Figure 2-1 you have to create the user accountsof the clients locally on the multiuser server.The accounts have to be identical tothe accounts of the clients.With this approach the server can authenticate a localaccount with identical login data automatically to an existing server account.Create the accounts on the multiuser server in the system control of Windows.InWindows 7,proceed as follows:1.In the "Control Panel"click on "User accounts>Manage Accounts CreateNew Account"2.Enter the user name of the client,for example,"MultiuserClient1".Select theaccount type,e.g."Standard user"and click on "Create Account"Figure 2-2:Create new accountName the account and choose an account typeStandard userStandard account users can use most software and change system settings that do not affect other users orthe security of the puter.Administrators have plete access to the puter and can make any desired changes.Based onWe remend that you protect every account with a strong password.Why is a standard account remended?Create AccountCancel☐The new account is created.3.Click the newly created account "MultiuserClient1"and then on "Create apassword".4.Enter the password for the "MultiuserClient1"account and confirm thepassword by clicking "Create password".Multiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/201872 EngineeringFigure 2-3:Create requestCreate a password for MultiuserClient1's accountMultiuserClient1Standard userpasswords for Web sites or work resources.To avoid losing data in the future,ask MultiuserClientl to make a password reset floppy disk.If the password contains capital letters,they must be typed the same way every time.How to create a strong passwordThe password hint will be visible to everyone who uses this puter.What is a password hint?Create password CancelThe password for the "MultiuserClient1"account is created.5.Repeat steps 1 to 4 for the accounts of the other clients.NoteWhen the server and the clients are member of the same Windows domain,theserver and the clients have to use the same LAN and they have to be created onthe domain controller.If the server and the clients are in the same Windows domain,the account of theclients must not be created on the multiuser server.More information can be found in the TIA Portal V15 Online help or the systemmanual "SIMATIC STEP 7 Basic/Professional V15 and SIMATIC WinCC V15":s://support.industry.siemens./cs/ww/en/view/109755202Multiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/201882 Engineering2.2.2Installing multiuser serverThe multiuser server can be installed together with the TIA Portal.During theinstallation of the TIA Portal,select the "Multiuser server"option.The multiuserserver can also be installed standalone without the TIA Portal.NoteA description for the automated installation can also be found on the productDVD.The tools for the configuration and management of the multiuser server are nowavailable in all languages of the TIA Portal.The multiuser server V14 and V15 can be used side by side.The multiuserserver V15 also supports TIA Portal projects from V14,with correspondingfunctional scope.In order to be able to work in a local session,you need a valid multiuser licensefor each local session.2.2.3Configuring the multiuser serverConfigure the multiuser server with the graphic tool "MultiUser Server V15Configuration".To do this,proceed as follows:1.Open the start menu by clicking the mand "Start All Programs SiemensAutomation TIA Portal Multiuser"2.Click the"Multiuser Server V15 Configuration"entry to open the configurationtool.3.Enter the desired data and click on "Install service".Select how many project versions are to be available as "Rollback"in "Numberof saved revisions:"Multiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/201892 EngineeringFigure 2-4:TIA Portal Multiuser Server-ConfigurationClient info:Service status:Server status:StoppedConnectlon settingsSecurityUMC Cient Station Certificate CN-localhost,OU-Siemens industry,O-Siemens AG.L-Genoa,S-italy,C-IT 1/1/2028 1:48StorageSaved revisions:UnlimitedEnglishNoteYou need enough free storage space on the multiuser server for the projectmanagement,depending on the respective project size and the number ofproject revisions held.4.Start the new multiuser server by clicking the "Start service"button in the"Server status"area.Figure 2-5:TIA Portal Multiuser Server-ConfigurationTLA Portal Multiuser Server V15-ConfigurationServer statusClientinfo:Multiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/2018102 EngineeringThe multiuser server is now configured and started.Figure 2-6:TIA Portal Multiuser Server-ConfigurationServer statusServer status:StartedConnection settingsPortTimeout profile:SecurityCreate a new self-signed certificate.NameSiemens Automation TIA Portal Multiuser Server V15 CN-MultiuserServerStorageSaved revisions:Action successfully cempletedEnglish2.2.4Managing the multiuser serverCreating server connectionConfigure a new server connection with the graphic tool "Multiuser Server V15Administration".To do this,proceed as follows:1.Click on the "Multiuser Server V15 Administration"entry to open theadministration tool.2.Add a connection to the desired multiuser server by clicking on "Add server".Enter the data for the management of the server in the "Add server"dialog.The data can be found in the "Configuration Tool"(see Figure 2-6).Click on"Add"to add the server connection.Multiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/2018112 EngineeringFigure 2-7:TIA Portal Multiuser Server-AdministrationAdministrationADMINISTRATIONAdd serverReloadAdd serverAdd server8735Preview:The new server connection is shown in the left area of the Administration Tool.3.Click the triangle of the new server connection to enable the connection.Confirm the certificate by clicking the "OK"button.Check the authenticity of the certificate by paring the fingerprint of thecertificate shown with the certificate that was created during the configuration.The fingerprint can be found in the "Server status"area in the "Client info"(seeFigure 2-6).Figure 2-8:TIA Portal Multiuser Server-AdministrationTIA Portal Multiuser Server V15-AdministrationTIA Portal Multiuser ServerADMINISTRATIONX Remove serverRelcadWindawn-thtWarningConfirm certificateAbbrechenMultiuser Engineering in the TIA PortalEntry ID:109740141,V1.3.06/201812
文档评分
    请如实的对该文档进行评分
  • 0
发表评论

"π³ 实操派",培养中高端PLC工程师,PLC培训-Codesys培训

项目实战 手把手教学 微信&电话 15850116008
超2000节系统化课程,汇川优秀自动化讲师亲授!学一门Codesys,玩800家PLC仅剩少量名额
点击免费试听

到实操派,学PLC就是快!

扫码领取工控文库VIP

钻石VIP先到先得

服务电话 & 微信:9:00-22:00

15850116008

苏州实操派科技有限公司

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

Copyright © 苏州实操派科技有限公司 2022 到实操派,学PLC就是快!工业自动化业务培训适用人群:成人 ( 苏ICP备2022021576号-3 )

公司地址:江苏省苏州市吴中区越溪街道天鹅荡路5号31B13

返回顶部